دوره 2، شماره 2 - ( 3-1391 )                   جلد 2 شماره 2 صفحات 234-221 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farshidianfar A, Soheili S. OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS . IJOCE 2012; 2 (2) :221-234
URL: http://ijoce.iust.ac.ir/article-1-88-fa.html
OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS . عنوان نشریه. 1391; 2 (2) :221-234

URL: http://ijoce.iust.ac.ir/article-1-88-fa.html


چکیده:   (20538 مشاهده)
This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonlinear Newmark method is employed to obtain the displacement, velocity and acceleration of different stories and TLCD. To illustrate the results, Kobe earthquake data is applied to the model. In order to obtain the best settings for TLCD, different parameters of TLCD are examined with constant mass quantity. The effective length, head loss coefficient, cross sectional ratio and length ratio of TLCD are assumed as the design variables. The objective is to reduce the maximum absolute and Root Mean Square (RMS) values of displacement and acceleration during earthquake vibration. The results show that the TLCDs are very effective and beneficial devices for decreasing the oscillations of high-rise buildings. It is indicated that the soil type highly affects the suitable parameters of TLCD subjected to the earthquake oscillations. This study helps the researchers to the better understanding of earthquake vibration of the structures including soil effects, and leads the designers to achieve the optimized TLCD for the high-rise buildings.
متن کامل [PDF 396 kb]   (7428 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: Optimal design
دریافت: 1391/3/24 | انتشار: 1391/3/26

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به دانشگاه علم و صنعت ایران می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Iran University of Science & Technology

Designed & Developed by : Yektaweb